Figures & Tables (cc-figures-tables)
When to trigger
- Representative images (blots, IHC, micrographs) shown without quantification
- A multi-panel figure has no clear narrative logic
- Worried about image-integrity standards (splicing, over-processing)
- Building a graphical abstract or supplemental display items
Cancer Cell figure logic
Each main figure should advance one step of the mechanistic argument and be readable on its own:
- Panels flow left-to-right / top-to-bottom as a mini-narrative (perturbation → readout → mechanism → consequence).
- Mechanistic figures typically combine schematic + functional data + in vivo and/or human validation.
- A figure usually carries discovery, validation, and a control panel together.
- Keep one main message per figure; push orthogonal corroboration to supplement.
Quantify everything representative
The signature Cancer Cell requirement: a representative image must be paired with quantification across biological replicates.
| Representative image |
Required quantification |
| Western blot |
Densitometry across n independent blots (normalized to loading) |
| IHC / IF micrograph |
Scored / counted across multiple fields and tumors (e.g., QuPath) |
| Flow plot |
Summary bar/dot plot of % or MFI across replicates |
| Tumor photo |
Tumor volume/weight curves with n, stats |
| Migration/invasion image |
Quantified across fields/replicates |
| Single-cell UMAP |
Proportions / DE stats, not just a colored embedding |
Show data points (superplots) for small n; never imply quantity from one picture.
Image integrity (Cell Press enforces)
- Keep uncropped, unprocessed raw blots/gels; include full-length blots in supplement with MW markers.
- No splicing of lanes without a clear dividing line and disclosure.
- Adjustments (brightness/contrast) must be linear and applied to the entire image, including controls.
- Do not duplicate, mirror, or reuse panels across figures.
- Disclose any grouping of images from different parts of the same gel.
Tables and the Key Resources Table
- The Key Resources Table (STAR Methods) is mandatory — see
cc-reporting-standards.
- Data tables (cohorts, mutation lists, screen hits) go to supplement; keep main tables minimal.
- Define every abbreviation and unit in legends.
Legends
- State
n, what one replicate is, the statistical test, the error-bar definition, and scale bars.
- Each panel letter referenced; magnification/scale bar on all micrographs.
- Antibodies / markers / treatments named in the legend.
Worked micro-example: fixing a "representative blot" panel
Before: Figure 2C is a single Western blot showing MARK7 down and cleaved-PARP up after treatment,
captioned "representative of independent experiments."
Why a Cancer Cell reviewer rejects it as evidence: one image cannot support a quantitative claim; the
reader cannot see variance, n, or whether the effect is consistent.
After: Figure 2C keeps the representative blot but adds 2C′ — densitometry normalized to loading
control across four independent lysates, plotted as a superplot (individual points + mean), with the
test and exact p in the legend. The uncropped full-length blot with MW markers moves to Figure S2. Now
the panel carries a claim, not an anecdote.
Panel-order sanity check (per main figure)
Read each figure left-to-right and ask whether it narrates one mechanistic step:
-
Perturbation — what was changed (knockdown/knockout/inhibitor), with the validation of that perturbation.
-
Readout — the phenotype or molecular consequence, quantified across replicates.
-
Mechanism — the intermediate that connects perturbation to readout (binding, flux, signaling).
-
Orthogonal confirmation — in vivo and/or human panel that the claim in the figure title needs.
If a panel does not serve the figure's one-sentence title, move it to the supplement.
Cancer Cell figure failure modes reviewers cite
- A migration/invasion or IHC figure with beautiful images but no per-field, per-tumor quantification.
- Tumor-growth curves without
n per arm, without the test, or truncated before humane endpoints.
- Flow plots shown as gated dot-plots only, with no summary statistic across mice/donors.
- A graphical abstract that asserts an axis (arrows implying causality) the main figures never establish.
- Kaplan-Meier survival curves with no numbers-at-risk and no censoring shown.
- Contrast/brightness pushed non-linearly, or a loading-control band reused across panels.
Checklist
Anti-patterns
- One representative blot/image as the entire evidence (no quantification)
- Bar charts hiding tiny
n; undefined error bars
- Spliced or over-contrasted blots; reused/duplicated panels
- Overcrowded figures mixing several unrelated messages
- Missing scale bars or unlabeled axes
- Beautiful schematic with no supporting data
Output format
【Per-figure message】Fig1: ... Fig2: ...
【Representative-without-quantification】flagged panels: [...]
【Image integrity】raw blots? linear adj? duplication check
【Legends】n / test / error bar / scale bar present? Y/N
【Validation panels】in vivo / human present where needed?
【Next step】cc-structured-abstract